features and benefits
With over 35 years experience in spray applications, Malvern Panalytical's Spraytec system provides the data needed to fully understand spray and atomization processes. Go to:
- Measure over a wide size range (0.1 to 2000 microns) without constantly changing optics.
- Respond to rapid changes in droplet size over time by taking up to 10,000 readings per second.
- Provide accurate, concentration-independent results using a patented multiple scatter analysis.
- Feature wide spray plumes with no risk of optical contamination.
- Easily view dynamic spray particle size changes through its unique historical size analysis software.
How it works
The Malvern Panalytical Spraytec uses laser diffraction technology to measure the size of spray droplets and particles. To do this, it measures the intensity of the scattered light when a laser beam penetrates a spray. This data is then analyzed to calculate the size of the droplets that created the scattering pattern.
The Spraytec system consists of the following main elements:
- a transmission modulecontains the collimated laser light source used to illuminate the aerosol during a measurement.
- a receiving modulewhich may contain one of two lenses (300mm or 750mm) that focus the scattered light from the spray onto a series of detectors. These detectors accurately measure the intensity of light scattered by spray droplets over a wide angular range.
- an optical benchwhich ensures that the transmitter and receiver are aligned. The length can be adjusted to suit different applications, with the longest bench being 2.5m.
- About Spraytechwhich monitors the system during the measurement process and analyzes the dispersion data to calculate spray size distributions. The results are displayed as a "size history" trend graph, allowing you to instantly see any change in droplet size over time.
specification
Generally
principle | laser light scattering. |
---|---|
Analyse | Mie and Fraunhofer scattering, including a patented multiple scattering analysis. |
data collection rate | Fast mode: 10 kHz. Continuous mode: 1Hz. |
Maximum Distances | Fast mode: 30 seconds. Continuous mode: 60 minutes. |
measuring shot | Internal: Based on light transmission or scattering. External: Based on TTL input or single key trigger. |
Synchronization of external devices | Via 2 TTL trigger outputs. |
optics
light source | He-Ne-Laser maximal 4 mW, 632,8 nm. |
---|---|
lens repair | Fourier (parallel beam). |
focal length of the lens | 300mm and 750mm. |
measuring range | 150 mm to 0.5 µm, over 5 µm more than 1 m. |
Detector
agreement | Array of 36 elements separated by records. |
---|---|
angle range | 0,015 – 17 Grad.** |
alignment | Automatically. |
scaling performance
particle size | 300mm lens: 0.1-900µm (Dv50: 0.5-600µm). 750mm lens: 2-2000µm (Dv50: 5-1600µm). |
---|---|
precision | Better than 1%.*** |
repeatability | Better than 1%.*** |
reproducibility | Better than 1%.*** |
Software
21 CFR Tel 11 | Enables a mode of operation that helps with ER/ES compliance. |
---|
system compliance
laser safety | Class 3R, IEC60825-1:2007 and CFR Chapter 1: Subchapter J: Part 1040 (CDRH). |
---|---|
official examinations | CE/FCC compliant. Meets the requirements of the European Low Voltage Directive. |
weight and dimensions
Laborsysteme | Optische Bank 950 mm: 950 mm x 550 mm x 610 mm (36 kg). Optische Bank 1400 mm: 37 kg 1400 x 550 x 610 (37 kg). |
---|---|
spray installation systems | Optische Bank 950 mm: 950 mm x 550 mm x 650 mm (36 kg). Optische Bank 1400 mm: 1400 x 550 x 650 (37 kg). |
System
Strength | 100/240 V, 50/60 Hz. |
---|---|
Product storage temperature | -20°C to +50°C. |
Operating temperature (°C) | +15°C to +40°C. |
humidity | Maximum 80% for temperatures up to 31°C, decreasing linearly to 50% at 40°C. No condensation. |
IP protection) | IP65 in normal use |
Nuts
* | This defines the maximum permissible distance between the outermost edge of the spray column and the Spraytec receiving lens. |
---|---|
** | Lens dependent. |
*** | It relates to the Dv50 measurement for NIST traceable latex standards. sample dependent. |
Accesories
Aerosol Positioning Accessory
Malvern Panalytical's Spraytec aerosol positioning accessory allows users to position aerosol cans or pump sprays relative to the Spraytec laser diffraction measurement zone during particle size and aerosol measurement.
This helps eliminate a major source of variability associated with spray measurements, allowing for reproducible testing of spray products for home and personal use.
air purge accessories
The air purge attachment prevents spray droplets from settling on the Spraytec optics when measuring large or concentrated spray plumes. This enables the routine characterization of products such as paint sprays or agrochemical application systems.
extraction accessories
The Spraytec Extraction Accessory provides a means of collecting and capturing droplets and spray particles during spray particle size measurement. This ensures that recirculation of spray particles is reduced during measurements and also helps manage the risks associated with user exposure to spray droplets.
Accessories for inhaler and nebulizer
The Spraytec inhaler and nebulizer accessories offer users the ability to reproducibly measure the particle size distributions of dry powders or droplets produced by metered dose inhalers, dry powder inhalers and nebulizers. Formulations can be quickly checked for the correct dispersion properties, giving researchers the detailed information they need to develop new inhaled drug delivery products.
Nasal Spray Accessory
The nasal spray accessory provides users with the ability to reproducibly measure particle or droplet size distributions generated by nasal drug delivery devices as part of bioequivalence studies or production quality control. Studies can also be conducted to determine how changes in nasal spray device, formulation, or device performance profile may affect the particle size of the spray administered.
wet dispersing accessories
The Spraytec wet dispersing accessory is an economical liquid sample dispersing device designed to measure samples in aqueous or non-aqueous dispersants.
Support
Protect your investment and ensure optimal performance, every time, with service plans from Malvern Panalytical.
When you purchase a Malvern Panalytical product, we understand that this is only the first phase of a working relationship that will last the lifetime of the instrument. Based on your needs, Malvern Panalytical can support your business.
counseling center
- Telephone and email support.
- Operators who are responsible for your call and ensure that your request is answered.
Training
- user training events.
download the programs
- A simple mechanism to get updates and new features
Malvern Panalytical Service Options - Choose the plan that's right for you:
Plan Platino de Malvern Panalytical
For labs where maximizing instrument uptime is critical to your daily performance. Our most responsive all-inclusive pricing plan takes care of unexpected repair bills should something unfortunate happen.
Malvern Panalytical Gold-Plan
Improve your lab's productivity while maintaining instrument efficiency. Still, getting this priority answer keeps your instrument's performance on track in combination with expert software and technical support.
Visita Malvern Panalytical Bronze
For laboratories looking to optimize instrument performance, regular preventive maintenance is essential.
Platinum-Plan | Golden Plane | visit bronze | |
---|---|---|---|
Annual PM/PV test | Sim | Sim | NO |
Phone/Email Support | Sim | Sim | NO |
priority answer | Sim | Sim | NO |
Emergency visits in case of breakdown* | Sim | Sim | NO |
parts included | Sim | NO | NO |
Technical and software support | Sim | Sim | Sim |
IQ/OQ (Pharma)*** | Sim | Sim | Sim |
*including labor and travel expenses***Available at extra cost
top applications
The flexibility of the Spraytec system makes it ideal for applications across a wide range of industries, from basic research and development to product quality control and batch release testing.
Provides accurate, reproducible spray size analysis in an easy-to-understand format, improving product understanding and control.
Orally and nasally inhaled drugs
Particle size is a key parameter in defining the deposition pattern and bioavailability of drug materials delivered to the nasal mucosa and respiratory system via sprays and inhalers. The Spraytec system can track size changes during individual device actuations, allowing particle dispersion dynamics to be identified along with device reproducibility. Therefore, formulations can be quickly evaluated for the right spray properties, reducing development times and improving drug delivery efficiency.
Webinar: Administering Nasal Spray Medication
Routine characterization of the atomizer
Measuring the droplet size produced by atomization systems is key to understanding the process and knowing about the environmental impact of spraying, for example in coatings or agrochemical applications.
The Spraytec's robust design, efficient air scavenging and multi-dispersion analysis ensure that measurements at high concentrations can be performed directly in a spray column, providing the real-time data needed to track changes in particle size during atomizer operation.
Application note: Characterization of spray nozzles for specific agrochemical applications
automotive applications
Spraytec's ability to measure at 10 kHz enables the resolution of droplet size variations observed during rapid ignition of automotive fuel injection systems. Providing flexible triggering options ensures that each injection event is fully captured. Atomization repeatability can then be evaluated and related to combustion efficiency.
Application note: Characterization of fuel injectors using high-speed laser diffraction droplet size measurements